Please use this identifier to cite or link to this item: http://hdl.handle.net/20.500.11960/2035
Full metadata record
DC FieldValueLanguage
dc.contributor.advisorCurado, António-
dc.contributor.advisorLopes, Sérgio Ivan-
dc.contributor.authorSilva, João Pedro da Cunha Alves Ferreira da-
dc.date.accessioned2018-06-27T15:46:21Z-
dc.date.available2018-06-27T15:46:21Z-
dc.date.issued2018-05-09-
dc.identifier.urihttp://hdl.handle.net/20.500.11960/2035-
dc.descriptionMestrado em Engenharia Civil e do Ambiente : Especialização em Construções Civis na Escola Superior de Tecnologia e Gestão do Instituto Politécnico de Viana do Castelopt_PT
dc.description.abstractSegundo a Organização Mundial de Saúde (OMS), o gás radão é o principal agente causador de cancro do pulmão, para a população não fumadora. Este gás está associado, em grande parte, à geologia dos locais e ao uso da rocha granítica como elemento construtivo, armazenando-se no interior dos edifícios, em cenários de pouca ventilação. A região do Minho surge em Portugal como uma das regiões mais afetadas ao nível da concentração de gás radão, acompanhando a geologia que o solo naturalmente oferece. O edifício tomado como Caso de Estudo no estudo desenvolvido, localiza-se no concelho de Ponte de Lima, distrito de Viana do Castelo. Trata-se de um edifício classificado, de caráter patrimonial, recentemente convertido em edifício escolar. O estudo experimental desenvolvido envolveu a monitorização da concentração de gás radão, temperatura e humidade relativa do ar interior num edifício escolar tomado como Caso de Estudo. Em simultâneo foi instrumentada a concentração dos gases dióxido e monóxido de carbono. Para além da sua caraterização construtiva, cada compartimento foi caraterizado em termos de ventilação - os períodos de ventilação desses compartimentos foram identificados mediante o preenchimento de inquéritos por parte dos ocupantes. Tendo como base os resultados experimentais obtidos, conclui-se que 77% das amostras ensaiadas registam concentrações de gás Radão acima do valor de referência segundo a Portaria nº 353-A/2013 [1], e 82% das amostras excedem o valor limite referido pela Diretiva Europeia 2013/59/EURATOM [2]. De forma a poder solucionar o problema da elevada concentração de gás Radão no interior dos edifícios, apresentam-se medidas gerais de mitigação, tais como a extração de gás e a selagem de pavimentos. A par das medidas gerais é apresentada uma medida mitigadora particular, a aplicar no compartimento do edifício estudado onde foram detetados os valores de concentração de gás Radão mais gravosos durante a 1ª e 2ª fase de monitorização.pt_PT
dc.description.abstractAccording to the World Health Organization (WHO), radon gas is the main causative agent of lung cancer, for the non-smoker population. This gas is associated, in large part, with the geology of the sites and the use of the granite rock as a constructive element, storing in its interior in scenarios of little ventilation. The Minho region appears in Portugal as one of the most affected regions by the concentration of radon gas, following the geology that the soil naturally offers. The building taken as Case Study in the study developed, is located in the municipality of Ponte de Lima which is inserted in the district of Viana do Castelo. It is a classified building, of patrimonial character, recently converted into a school building. The experimental study developed involved the monitoring of radon gas concentration, temperature and relative humidity of indoor air in the school building taken as Case Study. During that time, the concentration of the dioxide and carbon monoxide gases were also instrumented. In addition to their constructive characterization, each compartment was characterized in terms of ventilation - the ventilation periods of these compartments were identified through the completion of inquiries by the occupants. Based on the experimental results obtained, it is concluded that 77% of the samples tested have radon gas concentrations above the reference value according to Ordinance No. 353-A / 2013 [1] and in 82% of the samples exceed the limit value referred to in European Directive 2013/59 / EURATOM [2]. In order to solve the problem of high concentration of Radon gas inside buildings, general mitigation measures are presented, such as gas extraction and pavement sealing. In addition to the general measures, a particular mitigating measure is presented, to be applied in the compartment where the most severe values of concentration of Radon gas were detected during the 1st and 2nd monitoring phase.pt_PT
dc.language.isoporpt_PT
dc.rightsopenAccesspt_PT
dc.subjectRadãopt_PT
dc.subjectMonitorizaçãopt_PT
dc.subjectAlto Minhopt_PT
dc.subjectMitigaçãopt_PT
dc.subjectRadonpt_PT
dc.subjectMonitoringpt_PT
dc.subjectMitigationpt_PT
dc.titleMonitorização do gás radão num edifício escolar classificado do Alto Minhopt_PT
dc.typemasterThesispt_PT
thesis.degree.nameMestrado em Engenharia Civil e do Ambiente : Ramo Construções Civispt_PT
thesis.degree.levelMestrept_PT
thesis.degree.disciplineEngenharia Civilpt_PT
dc.identifier.tid201948184pt_PT
Appears in Collections:ESTG - Dissertações de mestrado

Files in This Item:
File Description SizeFormat 
Joao_Silva.pdf37.03 MBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.