dc.identifier.citationBranco, J. M., Matos, F. T., Lourenço, P. B., Demschner, T. & Rocha, P. (2019). Lateral tests on a two-story CLT house. In ABSE Symposium 2019 Guimarães Towards a Resilient Built Environment - Risk and Asset Management March 27-29, 2019, Guimarães, Portugal (pp. 967-977). http://doi.org/10.2749/guimaraes.2019.0969-
dc.identifier.isbn9783857481635-
dc.identifier.urihttp://hdl.handle.net/20.500.11960/2532-
dc.descriptionArtigo em ata de conferênciapt_PT
dc.description.abstractA two storey full-scale model of a CLT house, of 4.5 m x 9.1 m in-plane, with a height of 5.04 m, was tested under quasi-static monotonic (pushover). The main objectives were to investigate the 3-D system performance of a CLT structure subjected to lateral loads in terms of lateral strength and deformability capacity, global behaviour of the structure, frequency response of the structure, performance of connectors (mainly hold-downs and angle-brackets) and connections between CLT panels. Lateral loads have been applied on the storeys inducing torsion to the building. Loading procedure, number and disposition of connectors varied between tests. With this campaign it is intended to obtain results on: i) load-deformation response of a 3-D CLT structure subjected to lateral loads; ii) global response of the structure, focusing on the performance of CLT slabs subjected to in-plane loads, performance of parallel and perpendicular walls, and response of the structure near openings; iii) failure mechanisms and on the performance of connections between CLT panels and connectors. The outcomes of the full-scale CLT house tests will be used for further analytical and numerical analyses to help implement the new generation of Eurocode 8.pt_PT
dc.language.isoengpt_PT
dc.publisherInternational Association for Bridge and Structural Engineering (IABSE)pt_PT
dc.rightsopenAccesspt_PT
dc.subjectCross laminated timberpt_PT
dc.subjectSeismic designpt_PT
dc.subjectFull-scale testspt_PT
dc.subjectEurocode 8pt_PT
dc.titleLateral tests on a two-story CLT housept_PT
dc.typeconferenceObjectpt_PT
dc.peerreviewedyespt_PT
degois.publication.firstPage967pt_PT
degois.publication.lastPage977pt_PT
degois.publication.titleIABSE Symposium, Guimaraes 2019: Towards a Resilient Built Environment Risk and Asset Management - Reportpt_PT
degois.publication.locationGuimarãespt_PT
Appears in Collections:ESTG - Artigos indexados à WoS/Scopus

Files in This Item:
File Description SizeFormat 
LATERAL TESTS ON A TWO-STORY CLT HOUSE - IABSE_Guimaraes2019.pdf2.1 MBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.