dc.date.issued2024-
dc.identifier.citationNunes, L. J. R., Curado, A. & Lopes, S. I. (2024). Indoor radon mitigation strategies: The Alto Minho region (Northern Portugal) practical case. Indoor and Built Environment, 33(2), 269-286. https://doi.org/10.1177/1420326X231194877pt_PT
dc.identifier.issn1423-0070-
dc.identifier.urihttp://hdl.handle.net/20.500.11960/4728-
dc.description.abstractThe article explores techniques for mitigating indoor radon in buildings, including soil depressurization, anti-radon coatings and membranes, interior mechanical building pressurization, and natural and forced ventilation procedures. The effectiveness of each technique depends on various factors, such as indoor radon level or building construction type. The region of Alto Minho, Northern Portugal, mostly comprises single-family housing with different structures and materials, and performing an assessment stage is crucial for selecting the appropriate mitigation method. The ageing and declining population in the region suggests that the rehabilitation of existing buildings is more likely than the implementation of new construction. The article also emphasizes the potential impacts of soil depressurization and pressurization on soil geotechnical properties. Anti-radon barriers and mortars have been effectively used in high indoor radon concentration situations and can be combined with natural or forced ventilation procedures and real-time multi-parameter monitoring for improving indoor air quality and energy efficiency of buildings.pt_PT
dc.language.isoengpt_PT
dc.rightsopenAccesspt_PT
dc.subjectIndoor radonpt_PT
dc.subjectMitigation measurespt_PT
dc.subjectRadon exposurept_PT
dc.subjectPublic healthpt_PT
dc.subjectRadiation protectionpt_PT
dc.titleIndoor radon mitigation strategies: The Alto Minho region (Northern Portugal) practical casept_PT
dc.typearticlept_PT
dc.peerreviewedyespt_PT
degois.publication.firstPage269pt_PT
degois.publication.lastPage286pt_PT
degois.publication.volume33pt_PT
degois.publication.issue2pt_PT
degois.publication.titleIndoor and Built Environmentpt_PT
dc.identifier.doi10.1177/1420326X231194877-
Aparece nas colecções:ADiT-Lab - Publicações indexadas à WoS/Scopus
ESTG - Publicações indexadas à WoS/Scopus
proMetheus - Publicações indexadas à WoS/Scopus



Todos os registos no repositório estão protegidos por leis de copyright, com todos os direitos reservados.